The ANN-80 is a digital fire alarm annunciator, offering comprehensive system monitoring and detailed event logging, as shown in installation videos online.
Resources like YouTube demonstrate wiring and programming, while sites like Mungfali provide images of the device itself.
What is the ANN-80?
The Firelite ANN-80 is a sophisticated, microprocessor-based digital annunciator designed to provide detailed information about fire alarm system events. Online resources, including installation guides on platforms like YouTube, showcase its functionality.
It receives data from a compatible Fire Alarm Control Panel (FACP), displaying the status of various zones and initiating devices. The ANN-80 offers a clear, user-friendly interface for monitoring alarm, trouble, and supervisory conditions. Images available online demonstrate its physical appearance, aiding in identification and understanding its components.
Key Features and Benefits
The ANN-80 boasts several key features, including a large, easy-to-read LCD display, and comprehensive event logging capabilities, as highlighted in online installation videos. Benefits include enhanced situational awareness during emergencies, allowing for quicker and more informed responses.
Its ability to display specific zone information and device status minimizes confusion. Furthermore, the ANN-80’s compatibility with various FACPs, and its remote annunciator options, offer flexible system configurations. Online resources showcase these features visually.

ANN-80 Installation Guide
Proper installation requires careful mounting, correct wiring to the Fire Alarm Control Panel, and adherence to all local and national electrical codes, as shown online.
Mounting the ANN-80 Unit
Securely mounting the ANN-80 is crucial for reliable operation. Select a clean, dry, and accessible location, avoiding areas with excessive dust or moisture.
Utilize the provided mounting template to accurately mark screw locations on the mounting surface. Ensure the surface is capable of supporting the unit’s weight.
Fasten the ANN-80 using appropriate screws – typically pan head screws – ensuring they are tightened securely but not over-tightened. Verify the unit is level after installation for optimal display visibility.
Wiring Requirements and Connections
Proper wiring is essential for the ANN-80’s functionality. A dedicated 24VDC power supply is required, ensuring correct polarity.
Connect the ANN-80 to the Fire Alarm Control Panel (FACP) using the appropriate SLC (Signaling Line Circuit) wiring, adhering to the FACP manufacturer’s specifications.
Ensure all connections are secure and conform to local electrical codes. Use appropriately sized wiring and avoid sharp bends. Refer to installation videos for visual guidance on wiring configurations.
Connecting to the Fire Alarm Control Panel
Establishing communication between the ANN-80 and the FACP is crucial. Utilize the designated SLC terminals on both devices, ensuring compatibility with the FACP’s signaling protocol.
Address the ANN-80 within the FACP’s programming, assigning a unique device ID. Verify proper communication by initiating a system test from the FACP.
Refer to both the ANN-80 and FACP manuals for specific wiring diagrams and programming instructions. Online resources demonstrate this process visually.

ANN-80 Programming and Configuration
Programming the ANN-80 involves accessing a dedicated mode to customize system parameters, zone labels, and operational settings, as shown in online tutorials.
Understanding the Programming Mode
Entering the programming mode on the Firelite ANN-80 typically requires a specific sequence of key presses, often involving the “Enter” and “Scroll” buttons. Online resources, including YouTube installation guides, visually demonstrate this process.
Within this mode, users navigate a menu structure to adjust various settings. The display provides feedback, indicating the current parameter being modified. Careful attention to the manual is crucial, as incorrect settings can impact system functionality. Remember to save changes before exiting!
Setting System Parameters
System parameters on the ANN-80, accessed through programming mode, control core functionalities. These include adjusting alarm thresholds, configuring communication settings with the fire alarm control panel, and setting date/time information.
Referencing the user manual is vital, as specific parameter options vary. Online videos showcase the navigation process. Incorrect parameter settings can lead to false alarms or impaired system performance, so proceed with caution and verify all changes;
Zone Configuration and Labeling
Zone configuration within the ANN-80 allows for precise identification of alarm locations. Each zone represents a specific area protected by the fire alarm system. Labeling zones accurately – for example, “North Wing Lobby” or “Server Room” – is crucial for rapid response during an emergency.
The user manual details the programming steps for assigning zones and applying descriptive labels. Proper configuration ensures clear communication of alarm events to personnel, improving situational awareness.

ANN-80 Operation and Functionality
The ANN-80 displays alarm events with clear LED indicators, enabling quick response. System operation relies on proper programming and integration with the fire alarm control panel.
Normal Operation and LED Indicators
During normal operation, the ANN-80’s LEDs typically display a steady green indication, confirming a healthy system status and active communication with the connected fire alarm control panel. Any deviation from this indicates a potential issue requiring attention.
Individual zone LEDs illuminate to signify alarm activation, while flashing LEDs often denote a trouble or supervisory condition. Refer to the ANN-80 user manual for a complete decoding of LED patterns, ensuring accurate interpretation of system events and prompt response to any alerts.
Alarm Indication and Response
Upon alarm activation, the ANN-80 provides clear and immediate visual indication through illuminated zone LEDs, pinpointing the fire’s location. The system’s annunciator displays detailed alarm messages, aiding in swift and informed response.
Personnel should immediately verify the alarm, initiate evacuation procedures, and notify the fire department. The ANN-80’s event logging capabilities record alarm times and zones, crucial for post-incident analysis and reporting, as detailed in the user manual.
Silence and Reset Procedures
To silence an alarm, utilize the dedicated silence button on the ANN-80 front panel, acknowledging the event while allowing investigation. Note that silencing doesn’t reset the system; a full reset is required after addressing the cause.
A manual reset, typically involving a key switch, clears the alarm condition and returns the system to normal operation. Proper procedures, outlined in the ANN-80 user manual, ensure complete system restoration and accurate event logging.

Troubleshooting Common Issues
Common problems include power failures, communication errors with the control panel, and false alarms; consult the ANN-80 manual for diagnostic steps.
Online resources offer guidance on resolving these issues, ensuring system reliability.
Power Supply Problems
If the ANN-80 lacks power, first verify the main power source to the fire alarm control panel is active and within specified voltage limits.
Check the ANN-80’s internal power supply fuse; replacement requires a fuse of the correct amperage and type, as detailed in the user manual.
Inspect all wiring connections for looseness or corrosion. A faulty power supply or interrupted connection will prevent proper operation and display errors.
Ensure proper grounding to avoid electrical interference.
Communication Errors with the Control Panel
Communication failures between the ANN-80 and the fire alarm control panel often manifest as “Lost Communication” or similar error messages on the annunciator display.
Verify the data wiring – typically a two-wire or four-wire configuration – is secure and free from damage. Check for correct polarity and proper termination resistors.
Confirm the control panel is programmed to communicate with the ANN-80’s address. Refer to both the ANN-80 and control panel manuals for specific settings.
Inspect the communication loop for shorts or grounds.
False Alarm Troubleshooting
False alarms require systematic investigation. Begin by reviewing the ANN-80’s event log to pinpoint the initiating zone and time of the alarm.
Check the associated detection devices (smoke detectors, heat detectors, pull stations) for faults or sensitivity issues. Dust accumulation or insect activity can trigger false alarms.
Verify proper operation of all devices in the zone. Environmental factors like steam or aerosols can also cause unwanted activations. Consult the ANN-80 manual for sensitivity adjustments.
Document all findings and corrective actions.
ANN-80 Maintenance and Testing
Regular inspections, battery checks, and functional tests are crucial for reliable operation. The ANN-80 manual details procedures to verify system integrity and performance.
Consistent testing ensures all components are functioning as designed.
Regular Inspection Procedures
Routine visual inspections of the ANN-80 are paramount. Check for physical damage to the unit, ensuring the enclosure is secure and free from obstructions. Verify all wiring connections remain tight and undamaged, referencing installation guides if needed.
Inspect the LED indicators for proper operation during normal system conditions. Confirm the date and time displayed are accurate. Document all inspection findings in a logbook, noting any discrepancies or required maintenance. These procedures, detailed in the ANN-80 user manual, help maintain system reliability.
Battery Replacement Guidelines
The ANN-80 utilizes a sealed lead-acid battery for backup power. Replacement should occur every three to five years, or immediately upon a low-battery indication. Always disconnect the ANN-80 from the main power source before commencing battery replacement.
Use only manufacturer-approved replacement batteries with the specified voltage and capacity. Properly dispose of the old battery according to local regulations. Following these guidelines, outlined in the ANN-80 user manual, ensures uninterrupted operation during power outages.
Functional Testing and Verification
Regular functional testing of the ANN-80 is crucial for system reliability. Initiate tests by activating each detection zone individually and verifying corresponding annunciator indications. Confirm proper alarm sequencing, LED illumination, and any connected printer output.
Document all test results, noting any discrepancies. Refer to the ANN-80 user manual for detailed testing procedures. Consistent verification, performed by qualified personnel, ensures the system operates as designed during actual fire events.

ANN-80 Technical Specifications
The ANN-80 features a white enclosure, dimensions around 1280×720 pixels (as seen in online images), and operates with standard fire alarm control panels.
Physical Dimensions and Weight
The Firelite ANN-80 annunciator presents a sleek, white enclosure designed for clear visibility in emergency situations. Based on available imagery from sources like YouTube and image searches, the unit’s dimensions are approximately 1280×720 pixels when displayed digitally.
While precise physical measurements (height, width, depth) and the overall weight aren’t explicitly detailed in readily available online resources, the visual representation suggests a compact form factor suitable for wall mounting within a standard control panel setup. Further details are found in the manual.
Electrical Characteristics
The Firelite ANN-80 annunciator operates on a 24VDC power supply, commonly provided by the associated fire alarm control panel. While specific current draw isn’t detailed in the readily available online resources, it’s designed for efficient power consumption.
Wiring connections, as demonstrated in installation videos, utilize standard alarm circuitry. The unit is designed to integrate seamlessly with various control panel brands, ensuring compatibility and reliable operation. Detailed electrical specifications are available within the official user manual.
Environmental Operating Conditions
The Firelite ANN-80 annunciator is designed for indoor use within a temperature range of 32°F to 122°F (0°C to 50°C). It should be protected from direct exposure to moisture, extreme humidity, and corrosive environments.
Operating relative humidity should be between 10% and 95%, non-condensing. The unit is not intended for outdoor installation or locations subject to harsh weather conditions. Proper environmental control ensures reliable performance and longevity, as detailed in the official documentation.

ANN-80 Compliance and Standards
The ANN-80 meets UL listing requirements and adheres to NFPA standards for fire alarm systems, ensuring reliable performance and safety compliance.
These certifications guarantee the device functions correctly within established industry guidelines.
UL Listing and Approvals
The Firelite ANN-80 proudly carries a UL listing, signifying Underwriters Laboratories’ rigorous testing and verification of its safety and performance standards. This crucial approval confirms the annunciator meets nationally recognized benchmarks for fire alarm equipment.
UL evaluation encompasses electrical safety, component quality, and adherence to stringent construction requirements. Obtaining and maintaining this listing demonstrates Firelite’s commitment to providing reliable, high-quality products for life safety applications, offering peace of mind to installers and end-users alike.
NFPA Compliance
The Firelite ANN-80 is designed to comply with relevant National Fire Protection Association (NFPA) codes and standards, specifically those governing fire alarm systems. This includes adherence to NFPA 72, the National Fire Alarm and Signaling Code, which outlines requirements for installation, testing, and maintenance.
Compliance ensures the annunciator integrates seamlessly into a comprehensive fire protection strategy, supporting effective emergency response and life safety. Proper installation and configuration, following NFPA guidelines, are essential for optimal performance and code adherence.
Other Relevant Standards
Beyond NFPA 72 and UL listings, the Firelite ANN-80 may be subject to local and regional building codes impacting fire alarm system design. These standards often reference accessibility guidelines, ensuring clear alarm indication for all occupants, including those with disabilities.
Additionally, electrical codes, like those from the National Electrical Code (NEC), govern wiring practices and power supply requirements. Adhering to these standards ensures safe and reliable operation of the ANN-80 within the broader building infrastructure.

ANN-80 Accessories and Optional Modules
Optional modules include remote annunciators for expanded coverage and printer interfaces for detailed event logging, enhancing the ANN-80’s functionality.
Software tools aid in programming and configuration, streamlining system setup and maintenance.
Remote Annunciator Options
Expanding system visibility is easily achieved with Firelite ANN-80 remote annunciator options. These modules allow for duplicating alarm indications in geographically separated locations, crucial for large facilities.
Remote units mirror the main ANN-80 display, providing immediate awareness of alarm events to personnel across the site. Compatibility and communication protocols must be verified during installation, ensuring seamless integration with the central control panel. Proper wiring and configuration are essential for reliable operation, as demonstrated in available online installation guides.
Printer Interface Modules
Enhancing record-keeping, the Firelite ANN-80 supports printer interface modules for generating hard copies of alarm events and system logs. This provides a permanent, auditable trail for regulatory compliance and incident analysis;
Connecting a compatible printer allows for immediate documentation of alarms, silences, and resets. Configuration within the ANN-80 programming mode determines the printed information format. Ensure the printer is properly connected and configured according to the module’s documentation for reliable operation and clear, legible output.
Software and Programming Tools
Facilitating advanced configuration, the Firelite ANN-80 relies on specialized programming tools for system customization. While dedicated software isn’t explicitly detailed in readily available resources, the ANN-80 is programmed directly through its front panel interface.
Understanding the programming mode, as demonstrated in online installation guides, is crucial. Users navigate menus to set system parameters, configure zones, and label alarm points. Careful attention to the manual prevents programming errors and ensures optimal system performance.

ANN-80 System Diagrams and Schematics
Typical wiring diagrams, though not widely available online, are essential for proper installation and integration with compatible fire alarm control panels.
Understanding network configurations aids in troubleshooting and system expansion.
Typical Wiring Diagrams
Detailed wiring schematics for the ANN-80 are crucial for installers, demonstrating connections to the Fire Alarm Control Panel (FACP). These diagrams illustrate wiring for initiating devices, notification appliance circuits, and remote annunciators.
While comprehensive official diagrams aren’t broadly accessible online, resources like installation videos on platforms such as YouTube showcase practical wiring examples. Proper grounding and wire gauge adherence are vital for reliable operation. Incorrect wiring can lead to system malfunctions or false alarms, emphasizing the need for careful attention to detail during installation.
Network Configuration Examples
The ANN-80 often integrates into larger fire alarm systems, necessitating careful network configuration. While specific network topologies aren’t widely detailed in publicly available resources, understanding the communication protocols is key.
Typically, the ANN-80 connects to the FACP via a dedicated communication line. More complex systems might involve multiple annunciators networked together. Proper addressing and communication settings are vital for seamless data exchange. Troubleshooting network issues often involves verifying cable integrity and confirming correct device addressing within the system.
Block Diagrams of Internal Components
Detailed internal block diagrams of the ANN-80 are not readily available in public documentation or online resources like YouTube installation videos. However, it’s understood the unit comprises a microprocessor, memory for event logging, LED driver circuitry, and communication interfaces.
These components work together to receive signals from the FACP, process the data, and illuminate corresponding LEDs on the annunciator display. The power supply section provides regulated voltage to all internal circuits, ensuring reliable operation.
ANN-80 Frequently Asked Questions (FAQ)
Common questions involve compatibility with various control panels and programming nuances; online resources demonstrate basic setup, but advanced features require deeper understanding.
Avoid frequent programming errors by carefully reviewing the manual and available video tutorials.
Compatibility with Different Control Panels
The Firelite ANN-80 is designed for broad compatibility, though specific integrations vary. It commonly interfaces with Firelite MS-9600, Diamond, and EST systems, offering reliable data exchange.
However, successful integration with other manufacturers’ panels—like Notifier or Simplex—may require interface modules or custom programming. Always consult the ANN-80 documentation and the control panel’s manual to confirm compatibility and proper wiring configurations before installation. Online resources often highlight successful integrations.
Common Programming Mistakes
Frequently encountered errors when programming the ANN-80 include incorrect zone assignments, leading to mislabeled alarm locations. Another common mistake is improper configuration of communication settings, causing connection failures with the control panel.
Users sometimes overlook critical parameters like alarm thresholds or event logging preferences. Referencing the user manual and double-checking all entries before saving is crucial. Online tutorials often demonstrate correct programming sequences, preventing these issues.
Understanding Advanced Features
The ANN-80 boasts advanced features like custom event filtering, allowing users to prioritize specific alarm types. Its sophisticated event logging provides detailed historical data for analysis and reporting. Remote annunciator options extend system visibility beyond the main control panel.
Mastering these features requires careful study of the user manual and potentially, specialized training. Utilizing printer interface modules enables hardcopy documentation of critical events, enhancing record-keeping capabilities.

ANN-80 Safety Precautions
Always disconnect power before servicing. Follow electrical safety guidelines during installation and maintenance. Store the ANN-80 in a dry, secure location.
Electrical Safety Guidelines
Prior to any installation or maintenance work on the Firelite ANN-80, always disconnect the main power supply to the fire alarm control panel. This crucial step prevents electrical shock and potential damage to the system.
Qualified personnel, familiar with fire alarm systems and electrical codes, should perform all wiring and connections. Ensure proper grounding techniques are employed to minimize the risk of electrical hazards.
Never work on live circuits. Use insulated tools and wear appropriate personal protective equipment, including safety glasses and gloves. Inspect all wiring for damage before connecting it to the ANN-80.
Handling and Storage Instructions
When handling the Firelite ANN-80 annunciator, avoid dropping or subjecting it to physical shock. Store the unit in a clean, dry environment, protected from extreme temperatures and humidity.
Keep the ANN-80 in its original packaging when not in use to prevent damage during storage. Avoid stacking heavy objects on top of the unit. Ensure the storage area is free from dust and corrosive materials.
Inspect the unit for any signs of damage before installation. Proper handling and storage will ensure reliable performance.
Emergency Procedures
In the event of a fire alarm activation indicated by the ANN-80, immediately follow your established emergency evacuation plan. Do not attempt to troubleshoot the system during an actual alarm.
If the ANN-80 malfunctions, such as displaying incorrect information or failing to respond, notify the fire alarm system service provider immediately.
Ensure all personnel are familiar with the building’s fire safety procedures. Regular drills are crucial. Prioritize life safety above all else during any emergency situation.